Technical Specifications Hardware: Industrial grade printed circuit board Function: Excitation power signal processing Operating Temperature:‑25℃ ~ +70℃ Mounting: Cabinet internal rack installation
Functional Features Stable power conversion performance Hardware anti‑vibration design Built‑in transient surge suppression circuit
Application Scenarios Heavy‑duty gas turbine generator control cabinet Turbine excitation control subsystem
Performance Parameters Long‑term continuous operating stability Resist mechanical vibration inside control cabinet
Structural Characteristics Rack‑mount PCB assembly Multi‑point signal terminal connectors Gold‑plated contact pins for signal transmission Metal fixing mounting holes
Working Principle Receives input power signal, executes internal power conversion and signal conditioning, outputs processed excitation control signals to related turbine field components.
Installation Requirements Securely fix on cabinet internal rack. Keep away from strong vibration sources. Use shielded cables for external signal wiring.
Usage Notes Do not apply over‑rated voltage to signal terminals. Implement static protection during handling and replacement.














There are no reviews yet.