GE CE4002S1T2B5 Solenoid Drive Output Module

Product Brief Introduction: The GE CE4002S1T2B5 is a high‑power solenoid drive output module for GE industrial control system. It receives control command from main controller, outputs driving signal to field solenoid valves and electromagnetic actuators. Adopts surge absorption and over‑current protection circuit, suitable for industrial‑site electromagnetic load driving scenarios.
Tag:

Technical Specifications: Output Signal Type: Solenoid drive switching output Field Load Voltage: 24‑125VDC Over‑Current Protection: Hardware‑level over‑current limit protection Channel‑to‑Back‑Plane Isolation Voltage: 500V RMS Transient Surge Suppression: 1500V surge absorption circuit Operating Power Supply: +5VDC back‑plane power supply, field load power input Internal Bus: Proprietary GE rack back‑plane communication bus Operating Temperature: 0°C to +60°C Storage Temperature: ‑40°C to +85°C Relative Humidity: 5%‑95%, non‑condensing Mechanical Dimension: Standard rack plug‑in module Certifications: CE, industrial EMC standard compliance

Functional Features: Multi‑channel high‑power solenoid and electromagnetic actuator driving output capability. Built‑in hardware over‑current protection and surge absorption circuit for inductive‑load protection. Galvanic isolation between field output side and internal back‑plane circuit. Channel‑level fault detection for over‑current and load abnormality. Real‑time fault alarm and status information upload to host controller. Hot‑swap operation is not allowed under system powered‑on state.

Application Scenarios: Industrial‑site solenoid valve drive control for manufacturing plant. Electromagnetic actuator output control in petrochemical control cabinet. Legacy GE control system output channel spare‑part replacement project. Auxiliary equipment electromagnetic‑load control for power‑plant cabinet.

Structural Characteristics: Standard plug‑in card mechanical structure for dedicated rack installation. Front‑panel LED indicators for power supply, output channel status and fault alarm. Front‑side heavy‑current terminal block for field solenoid‑load wiring connection.

Working Principle: Main controller sends control command to module through rack internal back‑plane bus. On‑board logic circuit receives command and drives output power device. Output loop provides driving current for field solenoid load.

Installation Requirements: Insert module into matching slot of designated GE standard rack. Strictly implement cabinet grounding according to system safety specification. Field solenoid‑load wiring shall use thick‑gauge cables matching load current. Separate high‑power output wiring and weak‑signal control wiring. Confirm load power‑supply voltage range matches module specification before power‑on operation.




    Customers reviews

    There are no reviews yet.

    Be the first to review “GE CE4002S1T2B5 Solenoid Drive Output Module”

    Your email address will not be published. Required fields are marked *

    Search for products

    Back to Top
    Product has been added to your cart
    phone: +8613639522374
    to whats
    +8613639522374
    to whats
    +8613639522374
    email: anikaqx@gmail.com