Technical Specifications 24VDC power input; actuator drive output channel; integrated overcurrent, short-circuit and thermal protection. Operating temperature: -40℃ ~ +85℃.
Functional Features Control signal power amplification; real-time actuator stroke monitoring; automatic overload protection; channel fault alarm output.
Application Scenarios Diesel and gas engine fuel actuator closed-loop control circuits.
Performance Parameters Fast dynamic response, stable continuous drive capability, reliable automatic protection under overload conditions.
Structural Characteristics DIN rail metal shielding housing, pluggable power and signal terminals.
Working Principle Low-level control command from main controller is processed and amplified by internal power circuit. The output drive current controls actuator stroke, while the module monitors drive channel status continuously.
Installation Requirements Install close to actuator to reduce signal attenuation; separate high-power drive wiring and weak signal wiring.
Usage Notes Check actuator coil resistance for short circuit before power on; use anti-static protection during replacement.