Technical Specifications 24V DC / 230V AC optional. Ex explosion protection rating. IP66 enclosure. Multiple built-in buttons and indicator lamps. Operating temperature:-20°C ~ +60°C.
Functional Features Local manual operation. Equipment status indication. Explosion-proof flameproof housing. Mechanical protection for internal components. Terminal wiring chamber.
Application Scenarios Chemical plant, oil refinery, offshore platform, gas station and other zone 1/2 hazardous explosive areas for field local operation.
Performance Parameters Flameproof enclosure, reliable operation under explosive atmosphere. Operating temperature:-20~+60°C.
Structural Characteristics Flameproof metal housing, operation buttons and indicator windows, internal wiring terminal compartment, cable gland entries.
Working Principle Operate built-in buttons to send switch signals to control system; indicator lamps display equipment running or fault status. Flameproof housing prevents internal sparks from igniting surrounding explosive gas mixture.
Installation Requirements Mount on solid field support. Use certified explosion-proof cable glands. Complete protective grounding strictly according to hazardous area specification.
Usage Notes Do not open housing under power. Perform regular inspection of enclosure sealing and cable glands.














There are no reviews yet.