Allen-Bradley 1746-NT8 SLC 500 Thermocouple/mV Analog Input Module

Product Brief Introduction
The 1746-NT8 is an 8-channel thermocouple/millivolt analog input module for the SLC 500 series PLC. It supports multiple types of thermocouples and millivolt signal inputs, realizes high-precision temperature measurement and small signal acquisition, and adapts to SLC 500 programmable logic controller systems.
Tag:
Technical Specifications
Number of input channels: 8. Compatible thermocouple types: J, K, T, E, S, R, B, N. Compatible millivolt ranges: ±50mV, ±100mV. Resolution: 16-bit input / 14-bit output. Power supply: 5V DC backplane. Operating temperature range: 0°C to +60°C.
Functional Features
It is compatible with multiple thermocouple types. It has high-precision A/D conversion, open circuit detection function, electrical isolation between channels, built-in cold junction compensation, and supports multiple range configurations.
Application Scenarios
It applies to industrial temperature monitoring, heat treatment furnace temperature control, chemical reaction temperature acquisition, engine temperature testing, environmental test chamber monitoring, and process temperature control in manufacturing.
Performance Parameters
Measurement accuracy: ±3.0°C typical. Update time: 356ms to 4.05s selectable. Step response: 60ms. Operating temperature range: 0°C to +60°C. Common mode rejection ratio: 120dB @60Hz.
Structural Characteristics
It is a standard SLC 500 rack card with plastic front panel, screw terminal strip, status indicators, shielding layer design, and industrial-grade integrated circuits.
Working Principle
It receives input signals from thermocouples or millivolt sensors, converts them into digital values after signal amplification, cold junction compensation and A/D conversion, and transmits them to the PLC CPU through the backplane bus to realize accurate measurement and monitoring of temperature and small signals.
Installation Requirements
Install in any slot except slot 0 of the SLC 500 rack. Use thermocouple extension wires for wiring. Ensure reliable module grounding. Keep away from strong electromagnetic interference sources. Maintain ambient temperature within the rated range.
Usage Notes
Distinguish positive and negative poles of thermocouples during wiring. Use corresponding type of compensation wires. Regularly calibrate measurement accuracy. Avoid open input circuits. Check sensor wiring first when a fault occurs.




    Customers reviews

    There are no reviews yet.

    Be the first to review “Allen-Bradley 1746-NT8 SLC 500 Thermocouple/mV Analog Input Module”

    Your email address will not be published. Required fields are marked *

    Search for products

    Back to Top
    Product has been added to your cart
    phone: +8613639522374
    to whats
    +8613639522374
    to whats
    +8613639522374
    email: anikaqx@gmail.com